Honeywell Eclipse RatioAir Burner

  • Capacity range: 150,000 to 20,000,000 Btu/hr. (44 to 5860 kW)
  • Turndown: 30:1
  • Max. process temperature: 2800°F (1538°C)
  • Fuels: natural gas, propane, butane, landfill gas, low Btu gas
  • No gas adjustment with ratio control
  • Robust, reliable performance

Description

Application

Honeywell Eclipse RatioAir is a premium air heating burner ideally suited for applications that require: a velocity burner with integral packaged blower, high excess air and ratio control, use of unusual fuels (e.g. low Btu fuels), high chamber temperatures (up to 2500˚ F – 1370˚ C) and confined firing chambers. Eclipse RatioAir burners can deliver flame speeds of up to 500 feet per second to deliver improved temperature uniformity, product quality and system efficiency.

Technical

Honeywell Eclipse RatioAir is a nozzle-mix type burner designed for direct and indirect air heating in a wide range of applications including: Industrial Ovens and Furnaces, Glass Lehrs, Indirect Fired Air Heaters, RTO Incinerators, After Burners, Galvanizing Kettles and Waterbath Vaporizers.

The burner package includes a combustion air blower and an air/gas ratio regulator to fire over a wide gas turndown range with controlled ratio. Eclipse RatioAir burners are available with three different outlet tube velocity characteristics (standard, medium and high velocity), and are capable of outlet speeds of 250 ft/s with the medium velocity and 500 ft/s with the high velocity tubes.

The burner is designed for: Efficient Ratio Controlled Combustion, Reliable Burner Operation, Simple Burner Adjustment, Direct Spark Ignition and Multiple Fuel Capability. A wide variety of options and configurations are available due to the modular design of the burner.

Ask us for engineering or product support to configure your burner.

Eclipse RatioAir Burners with packaged blower:

RA0025 Maximum Input, 330,000 Btu/hr. (97 kW), 60 Hz
RA0040 Maximum Input, 505,000 Btu/hr. (148 kW), 60 Hz
RA0075 Maximum Input, 1,250,000 Btu/hr. (366 kW), 60 Hz
RA0100 Maximum Input, 1,311,000 Btu/hr. (384 kW), 60 Hz
RA0200 Maximum Input, 2,700,000 Btu/hr. (790 kW), 60 Hz
RA0300 Maximum Input, 3,960,000 Btu/hr. (1160 kW), 60 Hz
RA0500 Maximum Input, 6,160,000 Btu/hr. (1805 kW), 60 Hz
RA0750 Maximum Input, 9,000,000 Btu/hr. (2637 kW), 60 Hz
RA1000 Maximum Input, 10,900,000 Btu/hr. (3194 kW), 60 Hz
RA1500 Maximum Input, 16,335,000 Btu/hr. (4786 kW), 60 Hz
RA2000 Maximum Input, 21,050,000 Btu/hr. (6164 kW), 60 Hz

Technical Documentation

Download PDF files:

Eclipse RatioAir Brochure

Eclipse RatioAir Tech Info

Eclipse RatioAir Operating Instructions

RatioMatic Data Sheet:

Eclipse RA0025 Data Sheet

Contact us for other Eclipse RatioAir models.

Spare Parts

Spare Parts: click here

Then select Part Detective, and type in the model, like “RatioAir”